1.
Phys Med Biol ; 69(10)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38588671

RESUMEN

Objective. A novel x-ray field produced by an ultrathin conical target is described in the literature. However, the optimal design for an associated collimator remains ambiguous. Current optimization methods using Monte Carlo calculations restrict the efficiency and robustness of the design process. A more generic optimization method that reduces parameter constraints while minimizing computational load is necessary. A numerical method for optimizing the longitudinal collimator hole geometry for a cylindrically-symmetrical x-ray tube is demonstrated and compared to Monte Carlo calculations.Approach. The x-ray phase space was modelled as a four-dimensional histogram differential in photon initial position, final position, and photon energy. The collimator was modeled as a stack of thin washers with varying inner radii. Simulated annealing was employed to optimize this set of inner radii according to various objective functions calculated on the photon flux at a specified plane.Main results. The analytical transport model used for optimization was validated against Monte Carlo calculations using Geant4 via its wrapper, TOPAS. Optimized collimators and the resulting photon flux profiles are presented for three focal spot sizes and five positions of the source. Optimizations were performed with multiple objective functions based on various weightings of precision, intensity, and field flatness metrics. Finally, a select set of these optimized collimators, plus a parallel-hole collimator for comparison, were modeled in TOPAS. The evolution of the radiation field profiles are presented for various positions of the source for each collimator.Significance. This novel optimization strategy proved consistent and robust across the range of x-ray tube settings regardless of the optimization starting point. Common collimator geometries were re-derived using this algorithm while simultaneously optimizing geometry-specific parameters. The advantages of this strategy over iterative Monte Carlo-based techniques, including computational efficiency, radiation source-specificity, and solution flexibility, make it a desirable optimization method for complex irradiation geometries.


Asunto(s)
Método de Montecarlo , Rayos X , Fotones , Modelos Teóricos
2.
Med Phys ; 51(1): 447-463, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37947472

RESUMEN

BACKGROUND: Carbon nanotube-based cold cathode technology has revolutionized the miniaturization of X-ray tubes. However, current applications of these devices required optimization for large, uniform fields with low intensity. PURPOSE: This work investigated the feasibility and radiological characteristics of a novel conical X-ray target optimized for high intensity and high directionality to be used in a compact X-ray tube. METHODS: The proposed device uses an ultrathin, conical tungsten-diamond target that exhibits significant heat loading while maintaining a small focal spot size and promoting forward-directedness of the X-ray field through preferential attenuation of oblique-angled photons. The electrostatic and thermal properties of the theoretical tube were calculated and analyzed using COMSOL Multiphysics software. The production, transport, and calculation of radiological properties associated with the resultant X-ray field were performed using the Geant4 toolkit via its wrapper, TOPAS. RESULTS: Heat transfer analysis of this X-ray tube demonstrated the feasibility of a 200-kV electron beam bombarding the proposed target at a maximum current of 100 mA using a 1-ms symmetric duty cycle. The cathode of the X-ray tube was designed to be segmented into nine switchable electrical segments for modulation of the focal spot size from 0.4- to 10.8-mm. After importing the COMSOL-derived electron beam into TOPAS for X-ray production simulations, radiological analysis of the resultant field demonstrated high levels of intrinsic beam collimation while maintaining high intensity. A maximum dose rate of 17,887 cGy/min was calculated for 1-mm depth in water at 7-cm distance. CONCLUSIONS: The proposed X-ray tube design can create highly directional X-ray fields with superior fluence compared to that of current commercial X-ray tubes of comparable size.


Asunto(s)
Nanotubos de Carbono , Rayos X , Radiografía , Fluoroscopía , Programas Informáticos , Método de Montecarlo
3.
Arch Bone Jt Surg ; 11(11): 704-710, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38058974

RESUMEN

Objectives: Total knee arthroplasty (TKA) serves as an effective surgical treatment method for advanced osteoarthritis (OA). Nonetheless, it is associated with postoperative pain that can influence patients' functional outcome. This study aimed to compare the analgesic effect of subperiosteal and periarticular injection methods of a special local anesthetic in patients who underwent TKA. Methods: This double-blind prospective clinical study was conducted on patients with advanced knee OA who underwent TKA. Patients were randomly divided into two groups, with a local anesthetic (21 ml) administered either in periarticular (P group) or subperiosteal (S group) forms prior to wound closure. The local anesthetic consisted of lidocaine 2% (15 cc), dexmedetomidine (1 cc), and marcaine 0.5% (5 cc). A study-blinded orthopedic resident recorded postoperative pain levels using a 10-point visual analogue score (VAS) (0 indicating no pain, 10 indicating worst pain) at 6, 12, 24, and 48 hours after surgery. Results: A total of 40 patients (P and S group; n=20 each), consisting of 10 males (mean age=67.4 years old), were included in this study. The intensity of pain in the S group was significantly lower than in the P group 24 hours after surgery (mean VAS scores in the P group: 4±1 vs. the S group: 3.3±0.7, P=0.024). Furthermore, VAS scores at 6, 12, and 48 hours post-surgery were lower in the S group compared to the P group; however, the difference was not statistically significant (P>0.05). Conclusion: Our study indicated that subperiosteal injection of lidocaine, dexmedetomidine, and marcaine is more effective than periarticular injection, providing effective postoperative pain management after TKA.

4.
Med Phys ; 50(7): 4637-4644, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36893446

RESUMEN

BACKGROUND: Monte Carlo particle simulation has become the primary tool for designing low-energy miniature x-ray tubes due to the difficulties of physically prototyping these devices and characterizing their radiation fields. Accurate simulation of electronic interactions within their targets is necessary for modeling both photon production and heat transfer. Voxel-averaging can conceal hot spots in the target heat deposition profile that can threaten the integrity of the tube. PURPOSE: This research seeks a computationally-efficient method of estimating voxel-averaging error in energy deposition simulations of electron beams penetrating thin targets to inform the appropriate scoring resolution for a desired accuracy level. METHODS: An analytical model to estimate voxel-averaging along the target depth was developed and compared to results from Geant4 via its wrapper, TOPAS. A 200 keV planar electron beam was simulated to impinge tungsten targets of thicknesses between 1.5- and 12.5- µ m ${{\umu {\rm m}}}$ . For each target, the model was used to calculate the energy deposition ratio between voxels of varying sizes centered on the longitudinal midpoint of the target. Model-calculated ratios were compared to simulation outputs to gauge the model's accuracy. Then, the model was used to approximate the error between the point value of electron energy deposition and a voxel-based measurement. RESULTS: The model underestimates error to within 5% for targets less than 7.5- µ m ${{\umu {\rm m}}}$ in thickness with increasing error for greater thicknesses. For the 1.5- µ m ${{\umu {\rm m}}}$ target, calculations of the point-vs.-voxel energy deposition show an 11% averaging effect between the midpoint and a 1.5- µ m ${{\umu {\rm m}}}$ voxel. Energy deposition profiles along the target depth were also calculated in the Monte Carlo for reference. CONCLUSION: A simple analytical model was developed with reasonable accuracy to guide Monte Carlo users in estimating the appropriate depth-voxel size for thin-target x-ray tube simulations. This methodology can be adapted for other radiological contexts to increase robustness in point-value estimations.


Asunto(s)
Electrones , Fotones , Simulación por Computador , Método de Montecarlo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radiometría/métodos
5.
Pract Radiat Oncol ; 13(3): 217-230, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36115498

RESUMEN

PURPOSE: Using evidence-based radiation therapy to direct care for patients with breast cancer is critical to standardize practice, improve safety, and optimize outcomes. To address this need, the Veterans Affairs (VA) National Radiation Oncology Program (NROP) established the VA Radiation Oncology Quality Surveillance Program to develop clinical quality measures (QMs). The VA NROP contracted with the American Society for Radiation Oncology to commission 5 Blue Ribbon Panels for breast, lung, prostate, rectal, and head and neck cancers. METHODS AND MATERIALS: The Breast Cancer Blue Ribbon Panel experts worked collaboratively with the NROP to develop consensus QMs for use throughout the VA system, establishing a set of QMs for patients in several areas, including consultation and work-up; simulation, treatment planning, and treatment; and follow-up care. As part of this initiative, consensus dose-volume histogram (DVH) constraints were outlined. RESULTS: In total, 36 QMs were established. Herein, we review the process used to develop QMs and final consensus QMs pertaining to all aspects of radiation patient care, as well as DVH constraints. CONCLUSIONS: The QMs and expert consensus DVH constraints are intended for ongoing quality surveillance within the VA system and centers providing community care for Veterans. They are also available for use by greater non-VA community measures of quality care for patients with breast cancer receiving radiation.


Asunto(s)
Neoplasias de la Mama , Oncología por Radiación , Veteranos , Masculino , Humanos , Estados Unidos , Neoplasias de la Mama/radioterapia , Indicadores de Calidad de la Atención de Salud , Oncología por Radiación/métodos , Consenso
6.
Phys Med Biol ; 67(7)2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35272282

RESUMEN

Objective. A novel treatment modality is currently being developed that produces converging monoenergetic x-rays. Conventional application of dosimetric calibration as presented in protocol TG61 is not applicable. Furthermore, the dosimetry of the focal point of the converging beam is on the order of a few millimeters, requiring a high-resolution dosimeter. Here we present a procedure to calibrate radiochromic film for narrow-beam monoenergetic 60 keV photons as well as absolute dosimetry of monoenergetic focused x-rays. A study of the focal spot dose rate after passing through a bone-equivalent material was also done to quantify the effects of heterogeneous materials.Approach.This was accomplished by configuring a polyenergetic beam of equivalent energy using a clinical orthovoltage machine. Calibrated films were then used to perform absolute dosimetry of the converging beam by measuring the beam profile at various depths in water. Main Results.A method for calibrating radiochromic film has been developed and detailed that allows absolute dosimetry of a monoenergetic photon beam. Absolute dosimetry of a focused, mono-energetic beam resulted in a focal spot dose rate of ∼30 cGy min-1at a depth of 5 cm in water.Significance.This work serves to establish a dosimetry protocol for mono-energetic beam absolute dosimetry as well as the use of such a method for measurement of a novel teletherapy modality.


Asunto(s)
Dosimetría por Película , Radiometría , Calibración , Dosimetría por Película/métodos , Fotones/uso terapéutico , Radiometría/métodos , Agua
7.
Sci Rep ; 11(1): 19180, 2021 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-34584192

RESUMEN

We describe the development and analysis of a new teletherapy modality that, through a novel approach to targeted radiation delivery, has the potential to provide greater conformality than conventional photon-based treatments. The proposed system uses an X-ray lens to reflect photons from a conventional X-ray tube toward a focal spot. The resulting dose distributions have a highly localized peak dose, with lower doses in the converging radiation cone. Physical principles governing the design of this system are presented, along with a series of measurements analyzing various characteristics of the converging beam. The beam was designed to be nearly monoenergetic (~ 59 keV), with an energy bandwidth of approximately 10 keV allowing for treatment energies lower than conventional therapies. The focal spot was measured to be approximately 2.5 cm long and 4 mm wide. Mounting the proposed X-ray delivery system on a robotic arm would allow sub-millimeter accuracy in focal spot positioning, resulting in highly conformal dose distribution via the optimal placement of individual focal spots within the target volume. Aspects of this novel radiation beam are discussed considering their possible clinical application as a treatment approach that takes maximum advantage of the unique properties afforded by converging X-ray beam therapy.


Asunto(s)
Lentes , Fotones/uso terapéutico , Radioterapia Conformacional/instrumentación , Diseño de Equipo , Humanos , Método de Montecarlo , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica
8.
Adv Radiat Oncol ; 6(4): 100683, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33824935

RESUMEN

PURPOSE: To provide a series of suggestions for other Medical Physics practices to follow in order to provide effective radiation therapy treatments during the COVID-19 pandemic. METHODS AND MATERIALS: We reviewed our entire Radiation Oncology infrastructure to identify a series of workflows and policy changes that we implemented during the pandemic that yielded more effective practices during this time. RESULTS: We identified a structured list of several suggestions that can help other Medical Physics practices overcome the challenges involved in delivering high quality radiotherapy services during this pandemic. CONCLUSIONS: Our facility encompasses 4 smaller Houston Area Locations (HALs), a main campus with 8 distinct services based on treatment site (ie. Thoracic, Head and Neck, Breast, Gastrointestinal, Gynecology, Genitourinary, Hematologic Malignancies, Melanoma and Sarcoma and Central Nervous System/Pediatrics), a Proton Center facility, an MR-Linac, a Gamma Knife clinic and an array of brachytherapy services. Due to the scope of our services, we have gained experience in dealing with the rapidly changing pandemic effects on our clinical practice. Our paper provides a resource to other Medical Physics practices in search of workflows that have been resilient during these challenging times.

9.
PLoS One ; 13(10): e0205003, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30286184

RESUMEN

PURPOSE: To evaluate the uncertainty of radiomics features from contrast-enhanced breath-hold helical CT scans of non-small cell lung cancer for both manual and semi-automatic segmentation due to intra-observer, inter-observer, and inter-software reliability. METHODS: Three radiation oncologists manually delineated lung tumors twice from 10 CT scans using two software tools (3D-Slicer and MIM Maestro). Additionally, three observers without formal clinical training were instructed to use two semi-automatic segmentation tools, Lesion Sizing Toolkit (LSTK) and GrowCut, to delineate the same tumor volumes. The accuracy of the semi-automatic contours was assessed by comparison with physician manual contours using Dice similarity coefficients and Hausdorff distances. Eighty-three radiomics features were calculated for each delineated tumor contour. Informative features were identified based on their dynamic range and correlation to other features. Feature reliability was then evaluated using intra-class correlation coefficients (ICC). Feature range was used to evaluate the uncertainty of the segmentation methods. RESULTS: From the initial set of 83 features, 40 radiomics features were found to be informative, and these 40 features were used in the subsequent analyses. For both intra-observer and inter-observer reliability, LSTK had higher reliability than GrowCut and the two manual segmentation tools. All observers achieved consistently high ICC values when using LSTK, but the ICC value varied greatly for each observer when using GrowCut and the manual segmentation tools. For inter-software reliability, features were not reproducible across the software tools for either manual or semi-automatic segmentation methods. Additionally, no feature category was found to be more reproducible than another feature category. Feature ranges of LSTK contours were smaller than those of manual contours for all features. CONCLUSION: Radiomics features extracted from LSTK contours were highly reliable across and among observers. With semi-automatic segmentation tools, observers without formal clinical training were comparable to physicians in evaluating tumor segmentation.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Incertidumbre , Humanos , Variaciones Dependientes del Observador , Programas Informáticos , Tomografía Computarizada por Rayos X
10.
Med Phys ; 45(4): 1614-1621, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29493803

RESUMEN

PURPOSE: Using 3D printing to fabricate patient-specific devices such as tissue compensators, boluses, and phantoms is inexpensive and relatively simple. However, most 3D printing materials have not been well characterized, including their radiologic tissue equivalence. The purposes of this study were to (a) determine the variance in Hounsfield Units (HU) for printed objects, (b) determine if HU varies over time, and (c) calculate the clinical dose uncertainty caused by these material variations. METHODS: For a sample of 10 printed blocks each of PLA, NinjaFlex, ABS, and Cheetah, the average HU and physical density were tracked at initial printing and over the course of 5 weeks, a typical timeframe for a standard course of radiotherapy. After initial printing, half the blocks were stored in open boxes, the other half in sealed bags with desiccant. Variances in HU and density over time were evaluated for the four materials. Various clinical photon and electron beams were used to evaluate potential errors in clinical depth dose as a function of assumptions made during treatment planning. The clinical depth error was defined as the distance between the correctly calculated 90% isodose line and the 90% isodose line calculated using clinically reasonable, but simplified, assumptions. RESULTS: The average HU measurements of individual blocks of PLA, ABS, NinjaFlex, and Cheetah varied by as much as 121, 30, 178, and 30 HU, respectively. The HU variation over 5 weeks was much smaller for all materials. The magnitude of clinical depth errors depended strongly on the material, energy, and assumptions, but some were as large as 9.0 mm. CONCLUSIONS: If proper quality assurance steps are taken, 3D printed objects can be used accurately and effectively in radiation therapy. It is critically important, however, that the properties of any material being used in patient care be well understood and accounted for.


Asunto(s)
Impresión Tridimensional , Oncología por Radiación , Incertidumbre , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica
11.
Phys Imaging Radiat Oncol ; 8: 38-43, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33458415

RESUMEN

BACKGROUND AND PURPOSE: Postmastectomy radiotherapy (PMRT) is complex to plan and deliver, but could be improved with 3D-printed, patient-specific electron tissue compensators. The purposes of this study were to develop an algorithm to design patient-specific compensators that achieve clinical goals, to 3D-print the planned compensators, and validate calculated dose distributions with film and thermoluminescent dosimeter (TLD) measurements in 3D-printed phantoms of PMRT patients. MATERIALS AND METHODS: An iterative algorithm was developed to design compensators corresponding to single-field, single-energy electron plans for PMRT patients. The 3D-printable compensators were designed to fit into the electron aperture, with cerrobend poured around it. For a sample of eight patients, calculated dose distributions for compensator plans were compared with patients' (multi-field, multi-energy) clinical treatment plans. For all patients, dosimetric parameters were compared including clinical target volume (CTV), lung, and heart metrics. For validation, compensators were fabricated and irradiated for a set of six 3D-printed patient-specific phantoms. Dose distributions in the phantoms were measured with TLD and film. These measurements were compared with the treatment planning system calculated dose distributions. RESULTS: The compensator treatment plans achieved superior CTV coverage (97% vs 89% of the CTV receiving the prescription dose, p < 0.0025), and similar heart and lung doses (p > 0.35) to the conventional treatment plans. Average differences between calculated and measured TLD values were 2%, and average film profile differences were <2 mm. CONCLUSIONS: We developed a new compensator based treatment methodology for PMRT and demonstrated its validity and superiority to conventional multi-field plans through end-to-end testing.

12.
Int J Radiat Oncol Biol Phys ; 95(5): 1520-1526, 2016 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-27315666

RESUMEN

PURPOSE: To compare the treatment plans for accelerated partial breast irradiation calculated by the new commercially available collapsed cone convolution (CCC) and current standard TG-43-based algorithms for 50 patients treated at our institution with either a Strut-Adjusted Volume Implant (SAVI) or Contura device. METHODS AND MATERIALS: We recalculated target coverage, volume of highly dosed normal tissue, and dose to organs at risk (ribs, skin, and lung) with each algorithm. For 1 case an artificial air pocket was added to simulate 10% nonconformance. We performed a Wilcoxon signed rank test to determine the median differences in the clinical indices V90, V95, V100, V150, V200, and highest-dosed 0.1 cm(3) and 1.0 cm(3) of rib, skin, and lung between the two algorithms. RESULTS: The CCC algorithm calculated lower values on average for all dose-volume histogram parameters. Across the entire patient cohort, the median difference in the clinical indices calculated by the 2 algorithms was <10% for dose to organs at risk, <5% for target volume coverage (V90, V95, and V100), and <4 cm(3) for dose to normal breast tissue (V150 and V200). No discernable difference was seen in the nonconformance case. CONCLUSIONS: We found that on average over our patient population CCC calculated (<10%) lower doses than TG-43. These results should inform clinicians as they prepare for the transition to heterogeneous dose calculation algorithms and determine whether clinical tolerance limits warrant modification.


Asunto(s)
Algoritmos , Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Modelos Estadísticos , Hipofraccionamiento de la Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Mama/fisiopatología , Simulación por Computador , Femenino , Humanos , Órganos en Riesgo/efectos de la radiación , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Resultado del Tratamiento
13.
Radiat Oncol ; 9: 94, 2014 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-24735767

RESUMEN

PURPOSE: High cure rates for Hodgkin's lymphoma must be balanced with long-term treatment-related toxicity. Here we report an intensity-modulated radiation therapy (IMRT) technique that achieves adequate target coverage for mediastinal disease while minimizing high- and low-dose exposure of critical organs. METHODS AND MATERIALS: Treatment plans for IMRT and conventional anteroposterior-posteroanterior (AP-PA) techniques, with comparable coverage of the planning target volume (PTV), were generated for 9 female patients with mediastinal Hodgkin's lymphoma assuming use of inclined positioning, daily breath-hold, and CT-on-rails verification. Our "butterfly" IMRT beam arrangement involved anterior beams of 300°-30° and posterior beams of 160°-210°. Percentages of normal structures receiving 30 Gy (V30), 20 Gy (V20), and 5 Gy (V5) were tabulated for the right and left breasts, total lung, heart, left and right ventricles, left anterior descending coronary artery (LAD), and spinal cord. Differences in each variable, conformity index, homogeneity index, and V107% between the two techniques were calculated (IMRT minus conventional). RESULTS: Use of IMRT generally reduced the V30 and V20 to critical structures: -1.4% and +0.1% to the right breast, -1.7% and -0.9% to the left breast, -14.6% and -7.7% to the total lung, -12.2% and -10.5% to the heart, -2.4% and -14.2% to the left ventricle, -16.4% and -8.4% to the right ventricle, -7.0% and -14.2% to the LAD, and -52.2% and -13.4% to the spinal cord. Differences in V5 were +6.2% for right breast, +2.8% for left breast, +12.9% for total lung, -3.5% for heart, -8.2% for left ventricle, -1.5% for right ventricle, +0.1% for LAD, and -0.1% for spinal cord. Use of IMRT significantly reduced the volume of tissue receiving 107% of the dose (mean 754 cm3 reduction). CONCLUSIONS: This butterfly technique for IMRT avoids excess exposure of heart, breast, lung, and spinal cord to doses of 30 or 20 Gy; mildly increases V5 to the breasts; and decreases the V107%.


Asunto(s)
Corazón/efectos de la radiación , Enfermedad de Hodgkin/radioterapia , Pulmón/efectos de la radiación , Neoplasias del Mediastino/radioterapia , Radioterapia de Intensidad Modulada , Mama/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Enfermedad de Hodgkin/patología , Humanos , Neoplasias del Mediastino/patología , Órganos en Riesgo , Pronóstico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
14.
Med Phys ; 40(5): 051710, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23635258

RESUMEN

PURPOSE: The novel deterministic radiation transport algorithm, Acuros XB (AXB), has shown great potential for accurate heterogeneous dose calculation. However, the clinical impact between AXB and other currently used algorithms still needs to be elucidated for translation between these algorithms. The purpose of this study was to investigate the impact of AXB for heterogeneous dose calculation in lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). METHODS: The thorax phantom from the Radiological Physics Center (RPC) was used for this study. IMRT and VMAT plans were created for the phantom in the Eclipse 11.0 treatment planning system. Each plan was delivered to the phantom three times using a Varian Clinac iX linear accelerator to ensure reproducibility. Thermoluminescent dosimeters (TLDs) and Gafchromic EBT2 film were placed inside the phantom to measure delivered doses. The measurements were compared with dose calculations from AXB 11.0.21 and the anisotropic analytical algorithm (AAA) 11.0.21. Two dose reporting modes of AXB, dose-to-medium in medium (Dm,m) and dose-to-water in medium (Dw,m), were studied. Point doses, dose profiles, and gamma analysis were used to quantify the agreement between measurements and calculations from both AXB and AAA. The computation times for AAA and AXB were also evaluated. RESULTS: For the RPC lung phantom, AAA and AXB dose predictions were found in good agreement to TLD and film measurements for both IMRT and VMAT plans. TLD dose predictions were within 0.4%-4.4% to AXB doses (both Dm,m and Dw,m); and within 2.5%-6.4% to AAA doses, respectively. For the film comparisons, the gamma indexes (± 3%∕3 mm criteria) were 94%, 97%, and 98% for AAA, AXB_Dm,m, and AXB_Dw,m, respectively. The differences between AXB and AAA in dose-volume histogram mean doses were within 2% in the planning target volume, lung, heart, and within 5% in the spinal cord. However, differences up to 8% between AXB and AAA were found at lung∕soft tissue interface regions for individual IMRT fields. AAA was found to be 5-6 times faster than AXB for IMRT, while AXB was 4-5 times faster than AAA for VMAT plan. CONCLUSIONS: AXB is satisfactorily accurate for the dose calculation in lung cancer for both IMRT and VMAT plans. The differences between AXB and AAA are generally small except in heterogeneous interface regions. AXB Dw,m and Dm,m calculations are similar inside the soft tissue and lung regions. AXB can benefit lung VMAT plans by both improving accuracy and reducing computation time.


Asunto(s)
Algoritmos , Neoplasias Pulmonares/radioterapia , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Factores de Tiempo
15.
Int J Radiat Oncol Biol Phys ; 86(1): 83-90, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23582248

RESUMEN

PURPOSE: Intensity modulated radiation therapy (IMRT), compared with conventional 4-field treatment, can reduce the volume of bone marrow irradiated. Pelvic bone marrow sparing has produced a clinically significant reduction in hematologic toxicity (HT). This analysis investigated HT in Radiation Therapy Oncology Group (RTOG) 0418, a prospective study to test the feasibility of delivering postoperative IMRT for cervical and endometrial cancer in a multiinstitutional setting. METHODS AND MATERIALS: Patients in the RTOG 0418 study were treated with postoperative IMRT to 50.4 Gy to the pelvic lymphatics and vagina. Endometrial cancer patients received IMRT alone, whereas patients with cervical cancer received IMRT and weekly cisplatin (40 mg/m(2)). Pelvic bone marrow was defined within the treatment field by using a computed tomography density-based autocontouring algorithm. The volume of bone marrow receiving 10, 20, 30, and 40 Gy and the median dose to bone marrow were correlated with HT, graded by Common Terminology Criteria for Adverse Events, version 3.0, criteria. RESULTS: Eighty-three patients were eligible for analysis (43 with endometrial cancer and 40 with cervical cancer). Patients with cervical cancer treated with weekly cisplatin and pelvic IMRT had grades 1-5 HT (23%, 33%, 25%, 0%, and 0% of patients, respectively). Among patients with cervical cancer, 83% received 5 or more cycles of cisplatin, and 90% received at least 4 cycles of cisplatin. The median percentage volume of bone marrow receiving 10, 20, 30, and 40 Gy in all 83 patients, respectively, was 96%, 84%, 61%, and 37%. Among cervical cancer patients with a V40 >37%, 75% had grade 2 or higher HT compared with 40% of patients with a V40 less than or equal to 37% (P =.025). Cervical cancer patients with a median bone marrow dose of >34.2 Gy also had higher rates of grade ≥ 2 HT than did those with a dose of ≤ 34.2 Gy (74% vs 43%, P=.049). CONCLUSIONS: Pelvic IMRT with weekly cisplatin is associated with low rates of HT and high rates of weekly cisplatin use. The volume of bone marrow receiving 40 Gy and the median dose to bone marrow correlated with higher rates of grade ≥ 2 toxicity among patients receiving weekly cisplatin (cervical cancer patients). Evaluation and limitation of the volume of bone marrow treated with pelvic IMRT is warranted in patients receiving concurrent chemotherapy.


Asunto(s)
Médula Ósea/efectos de la radiación , Neoplasias Endometriales/radioterapia , Órganos en Riesgo/efectos de la radiación , Huesos Pélvicos/efectos de la radiación , Radioterapia de Intensidad Modulada/efectos adversos , Neoplasias del Cuello Uterino/radioterapia , Adulto , Anciano , Cisplatino/administración & dosificación , Terapia Combinada/métodos , Estudios de Factibilidad , Femenino , Humanos , Intestino Delgado/efectos de la radiación , Irradiación Linfática/métodos , Persona de Mediana Edad , Tratamientos Conservadores del Órgano/métodos , Pelvis , Cuidados Posoperatorios , Estudios Prospectivos , Dosis de Radiación , Traumatismos por Radiación/patología , Traumatismos por Radiación/prevención & control , Fármacos Sensibilizantes a Radiaciones/administración & dosificación , Radioterapia de Intensidad Modulada/métodos , Análisis de Regresión , Vejiga Urinaria/efectos de la radiación , Neoplasias del Cuello Uterino/tratamiento farmacológico , Vagina
16.
Int J Radiat Oncol Biol Phys ; 84(1): e23-8, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22543211

RESUMEN

PURPOSE: To determine the feasibility of pelvic intensity modulated radiation therapy (IMRT) for patients with endometrial cancer in a multi-institutional setting and to determine whether this treatment is associated with fewer short-term bowel adverse events than standard radiation therapy. METHODS: Patients with adenocarcinoma of the endometrium treated with pelvic radiation therapy alone were eligible. Guidelines for target definition and delineation, dose prescription, and dose-volume constraints for the targets and critical normal structures were detailed in the study protocol and a web-based atlas. RESULTS: Fifty-eight patients were accrued by 25 institutions; 43 were eligible for analysis. Forty-two patients (98%) had an acceptable IMRT plan; 1 had an unacceptable variation from the prescribed dose to the nodal planning target volume. The proportions of cases in which doses to critical normal structures exceeded protocol criteria were as follows: bladder, 67%; rectum, 76%; bowel, 17%; and femoral heads, 33%. Twelve patients (28%) developed grade ≥2 short-term bowel adverse events. CONCLUSIONS: Pelvic IMRT for endometrial cancer is feasible across multiple institutions with use of a detailed protocol and centralized quality assurance (QA). For future trials, contouring of vaginal and nodal tissue will need continued monitoring with good QA and better definitions will be needed for organs at risk.


Asunto(s)
Neoplasias Endometriales/radioterapia , Órganos en Riesgo/diagnóstico por imagen , Radioterapia de Intensidad Modulada/métodos , Adulto , Anciano , Neoplasias Endometriales/patología , Neoplasias Endometriales/cirugía , Estudios de Factibilidad , Femenino , Cabeza Femoral/efectos de la radiación , Humanos , Intestinos/efectos de la radiación , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Cuidados Posoperatorios , Radiografía , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada/efectos adversos , Recto/efectos de la radiación , Vejiga Urinaria/efectos de la radiación , Vagina/diagnóstico por imagen
17.
Med Dosim ; 37(4): 374-82, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22513213

RESUMEN

To decrease the risk of late toxicities in Hodgkin's lymphoma (HL) patients treated with radiation therapy (RT) (HL), involved field radiation therapy (IFRT) has largely replaced the extended fields. To determine the out-of-field dose delivered from a typical IFRT to surrounding critical structures, we measured the dose at various points in an anthropomorphic phantom. The phantom is divided into 1-inch-thick slices with the ability to insert TLDs at 3-cm intervals grid spacing. Two treatment fields were designed, and a total of 45 TLDs were placed (equally spaced) at the margin of the each of the 2 radiation fields. After performing a computed tomography simulation, 2 treatment plans targeting the mediastinum, a typical treatment field in patients with early stage HL, were generated. A total dose of 3060 cGy was delivered to the gross tumor volume for each field consecutively. The highest measured dose detected at 1 cm from the field edge in the planning target volume was 496 cGy, equivalent to 16% of the isocentric dose. The dose dropped significantly with increasing distance from the field edge. It ranged from 1.1-3.9% of the isocentric dose at a distance of 3.2-4 cm to <1.6% at a distance of >6 cm. Although the computer treatment planning system (CTPS) frequently underestimated the dose delivered, the difference in dose between measured and generated by CTPS was <2.5% in 90 positions measured. The collateral dose of radiation to breasts from IFRT is minimal. The out-of-field dose, although mildly underestimated by CTPS, becomes insignificant at >3 cm from the field edge of the radiation field.


Asunto(s)
Mama/efectos de la radiación , Enfermedad de Hodgkin/diagnóstico por imagen , Enfermedad de Hodgkin/radioterapia , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Radiometría/instrumentación , Dosificación Radioterapéutica , Neoplasias de la Mama , Femenino , Humanos , Órganos en Riesgo/diagnóstico por imagen , Radiografía , Radioterapia Conformacional/métodos
18.
Int J Radiat Oncol Biol Phys ; 82(1): 256-62, 2012 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-21093170

RESUMEN

PURPOSE: To evaluate variations in bladder and rectal volume and the position of the vaginal vault during a 5-week course of pelvic intensity-modulated radiation therapy (IMRT) after hysterectomy. METHODS AND MATERIALS: Twenty-four patients were instructed how to fill their bladders before simulation and treatment. These patients underwent computed tomography simulations with full and empty bladders and then underwent rescanning twice weekly during IMRT; patients were asked to have full bladder for treatment. Bladder and rectal volumes and the positions of vaginal fiducial markers were determined, and changes in volume and position were calculated. RESULTS: The mean full and empty bladder volumes at simulation were 480 cc (range, 122-1,052) and 155 cc (range, 49-371), respectively. Bladder volumes varied widely during IMRT: the median difference between the maximum and minimum volumes was 247 cc (range, 96-585). Variations in rectal volume during IMRT were less pronounced. For the 16 patients with vaginal fiducial markers in place throughout IMRT, the median maximum movement of the markers during IMRT was 0.59 cm in the right-left direction (range, 0-0.9), 1.46 cm in the anterior-posterior direction (range, 0.8-2.79), and 1.2 cm in the superior-inferior direction (range, 0.6-2.1). Large variations in rectal or bladder volume frequently correlated with significant displacement of the vaginal apex. CONCLUSION: Although treatment with a full bladder is usually preferred because of greater sparing of small bowel, our data demonstrate that even with detailed instruction, patients are unable to maintain consistent bladder filling. Variations in organ position during IMRT can result in marked changes in the position of the target volume and the volume of small bowel exposed to high doses of radiation.


Asunto(s)
Neoplasias Endometriales/radioterapia , Movimiento , Radioterapia de Intensidad Modulada , Recto/diagnóstico por imagen , Vejiga Urinaria/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia , Vagina/diagnóstico por imagen , Adulto , Simulación por Computador , Agua Potable/administración & dosificación , Neoplasias Endometriales/diagnóstico por imagen , Neoplasias Endometriales/cirugía , Femenino , Marcadores Fiduciales , Humanos , Histerectomía , Intestino Delgado/diagnóstico por imagen , Persona de Mediana Edad , Tamaño de los Órganos , Cuidados Posoperatorios/métodos , Estudios Prospectivos , Recto/anatomía & histología , Tomografía Computarizada por Rayos X , Uretra/diagnóstico por imagen , Vejiga Urinaria/anatomía & histología , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/cirugía , Vagina/anatomía & histología
19.
Int J Radiat Oncol Biol Phys ; 82(2): 708-14, 2012 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-21444161

RESUMEN

PURPOSE: Many patients with left-sided breast cancer receive adjuvant radiotherapy during deep-inspiration breath hold (DIBH) to minimize radiation exposure to the heart. We measured the displacement of the left anterior descending artery (LAD) and heart owing to cardiac motion during DIBH, relative to the standard tangential fields for left breast cancer radiotherapy. METHODS AND MATERIALS: A total of 20 patients who had undergone computed tomography-based coronary angiography with retrospective electrocardiographic gating were randomly selected for the present study. The patients underwent scanning during DIBH to control the influence of respiration on cardiac motion. Standard medial and lateral tangential fields were placed, and the LADs were contoured on the systolic- and diastolic-phase computed tomography data sets by the clinicians. Displacement of the LAD during cardiac contractions was calculated in three directions: toward the posterior edge of the treatment fields, left-right, and anteroposterior. Displacement of the entire heart was measured on the maximal and minimal intensity projection computed tomography images. RESULTS: The mean displacement of the LAD from cardiac contraction without the influence of respiration for 20 patients was 2.3 mm (range, 0.7-3.8) toward the posterior edge of the treatment fields, 2.6 mm (range, 1.0-6.8) in the left-right direction, and 2.3 mm (range, 0.6-6.5) in the anteroposterior direction. At least 30% of the LAD volume was displaced >5 mm in any direction in 2 patients (10%), and <10% of the LAD volume was displaced >5 mm in 10 patients (50%). The extent of displacement of the heart periphery during cardiac motion was negligible near the treatment fields. CONCLUSIONS: Displacement of the heart periphery near the treatment fields was negligible during DIBH; however, displacement of the LAD from cardiac contraction varied substantially between and within patients. We recommend maintaining ≥ 5 mm of distance between the LAD and the field edge for patients undergoing breast cancer radiotherapy during DIBH.


Asunto(s)
Neoplasias de la Mama/radioterapia , Angiografía Coronaria/métodos , Vasos Coronarios/fisiología , Inhalación , Movimiento/fisiología , Contracción Miocárdica , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Corazón , Humanos , Radioterapia Adyuvante , Tomografía Computarizada por Rayos X/métodos
20.
Pract Radiat Oncol ; 2(3): 201-209, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-24674124

RESUMEN

PURPOSE: The Radiation Therapy Oncology Group (RTOG) has published consensus guidelines for contouring relevant anatomy for postmastectomy radiation therapy (RT). How these contours relate to current treatment practices is unknown. We analyzed the dose-volume histograms (DVHs) for these contours using current clinical practice at University of Texas MD Anderson Cancer Center and compared them with the proposed treatment plans to treat RTOG-defined targets to full dose. METHODS AND MATERIALS: We retrospectively analyzed treatment plans for 20 consecutive women treated with postmastectomy RT for which the treatment targets were the chest wall (CW), level III axilla (Ax3), supraclavicular (SCV), and internal mammary (IM) nodes. The RTOG consensus definitions were used to contour the following anatomic structures: CW; level I, II, and III axillary nodes (Ax1, Ax2, Ax3); SCV; IM; and heart (H). DVHs for these contours and the ipsilateral lung were generated from clinically designed treatment that had actually been delivered to each patient. For comparison regarding dose to normal tissue, new treatment plans were generated with the goal of covering 95% of the anatomic contours to 45 Gy. RESULTS: The prescribed dose was 50 Gy in each case. The mean percent of volumes that received 45 Gy (V45) for the RTOG guideline-based contours were CW 74%, Ax1 84%, Ax2 88%, Ax3 96%, SCV 84%, and IM 80%. Mean heart V10 values were 11% for treatment of left-sided tumors and 6% for right-sided tumors. Mean ipsilateral lung V20 values were 28% for left-sided tumors and 34% for right-sided tumors. For the contour-based plans, mean V45 values were CW 94%, Ax1 95%, Ax2 97%, Ax3 98%, SCV 98%, and IM 85%. Mean heart V10 values were 14% for treatment of left-sided tumors and 12% for right-sided tumors. Mean ipsilateral lung V20 values were 32% for left-sided tumors and 45% for right-sided tumors. CONCLUSIONS: Clinically derived treatment plans, which have proven efficacy and are the current standard, cover 74% to 96% of the anatomy-based RTOG consensus volumes to the prescription dose. This discrepancy should be considered if treatment planning protocol guidelines are designed to incorporate these new definitions.